Applied Biosystems® 7500 Fast Real-Time PCR System
Catalog number: 4351106
Description:
The Applied Biosystems® 7500 Fast Real-Time PCR System offers maximum performance in the minimum time. Fully optimized for Fast cycling, the 7500 Fast delivers high-quality results in as little as 30 minutes. We supply a Dell™ Notebook computer with the 7500 Fast System.
- Specially designed Fast block ensures thermal uniformity at top speeds.
- Faster ramp rates enable rapid results without compromising extension times or assay quality.
- Fast optical plates ensure excellent precision in 10-30 ul reaction volumes.
- Use TaqMan® Fast Universal PCR Master Mix to run multiple Fast assays on one plate.
- Finish more runs per day with the excellent performance equivalent to that offered by the 7500 System.
High Resolution Melting Analysis
The Applied Biosystems® High Resolution Melting (HRM) Software is the easiest to use melting analysis software enabling real-time PCR melt curve assays to be used more accurately for mutation scanning and genotyping. The HRM Software is available on the 7500 Fast Real-Time PCR System, which delivers precise results in a standard 96-well format.
Use the Applied Biosystems® High Resolution Melting (HRM) Software to perform more sophisticated melting analysis with an easy to follow workflow and minimal subjective data analysis steps.
- Shortens analysis time by auto-calling genotypes and automatically omitting the no template controls.
- Minimizes subjective analysis by automatically grouping unknown variant clusters.
- No temperature shift required – distinguish between homozygous mutants and wild type more easily.
- Allows easy data review with customizable multi-plot views, expandable windows and one-click color assignment to highlight curves of interest.
- Facilitates data presentation with the option to export data and graphs directly to PowerPoint or as JPEG files.
- 21 CFR Part 11 Module available
- The SDS v1.4 21CFRp11 Module is a powerful tool for assisting with 21CFRp11 compliance, while still offering the flexibility of user-customizable configuration settings.
- Individual user log-ins can be added for up to four user groups, each group with designated permission settings.
- User-customizable permission settings include fourteen system activities, e-signature authority designation, and additional security settings to give you maximum control over your compliance efforts.
- Audit trails can be enabled or disabled depending on your traceability needs.
- A selection of e-signatures is available to ease e-signatures into your workflow.
One System, Many Applications
Applications include gene expression analysis, pathogen quantitation, SNP genotyping, isothermal and +⁄– assays utilizing internal positive controls. To facilitate many of these applications, Applied Biosystems® provides preformulated, ready-to-use, quality-tested, TaqMan® assays for use with the 7500 Fast system. Now you can reduce your assay optimization efforts.
Specifications:
Calibrated Dye: |
Cy3, Cy5, FAM, JOE, NED, ROX, SYBR Green, TAMRA, Texas Red, VIC |
Capacity: |
1 x 96-well plate (Fast), 12 x 8-tube strips |
Dimensions: |
34 cm (13.39 in) (W) x 49 cm (19.29 in) (H) x 45 cm (17.72 in) (D) |
Dynamic Range: |
9 logs of linear dynamic range |
External Computer: |
Laptop computer provided |
For Use With (Equipment): |
7500 Fast System |
Format: |
8-well strips, 96-well plate |
Optics: |
CCD Camera, Five excitation and five emission filters, Halogen light source |
Passive Reference Dye: |
Other Passive Reference Dye, ROX (Pre-mixed), ROX (Separate Tube) |
Peak Block Ramp Rate: |
5.5°C ⁄ sec |
Precision: |
Distinguish between 5,000–10,000 genome equivalents (two-fold copy number difference) with 99.7% confidence |
Product Size: |
1 system |
Reaction Speed: |
Fast, Standard |
Reaction Volume Range: |
10-30 µl |
Run Time: |
<2 hrs (Standard), 36 min (Fast) |
Sample Ramp Rate: |
Fast mode: ± 3.5°C ⁄ sec, Standard mode: ± 1.6°C⁄sec |
Sensitivity: |
Down to 1 copy of human RNAse P gene |
Temperature Accuracy: |
±0.5°C |
Temperature Range (Metric): |
4.0-99.9 °C |
Temperature Uniformity: |
±1°C |
Thermal Cycling System: |
Peltier-Based System |
Throughput: |
4 to 5 96-well plates per day |
Weight: |
34 kg (75 lb) |